Type
4/2
Overlap
positive (closed)
suitable solenoid coil
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
Registrati subito per accedere al nostro shop online.
Register now and access our complete product range and many exclusive services.
Dettagli del prodotto su
HK DKE 1 632 2 X00DC
Type
4/2
Overlap
positive (closed)
suitable solenoid coil
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
Piston type
2/2 [PB/A/T]-[PA/B/T]
Design material
spring return
Tutte le caratteristiche
Caratteristiche
Max. working pressure
- P, A, B: max. 350 bar / T: max. 210 bar
Design
- 4/2-way valve or 4/3-way valve
- 5-chamber valve
- with manual override function
- for DC coils
Connector
- ISO/Cetop 05 size 10
Flow rate
- max. 150 l/min (note characteristic curves)
Mounting
- 4 pcs. hexagon socket screw M 6 x 40 12.9
- screw set HK M6 40 for 1 basic valve. In vertical stacking applications with intermediate plates, the use of the appropriate longer screws are required.
Customs tariff number
- 84812010
Tutte le caratteristiche
Descrizione del prodotto
Avvertenze
Descrizione
Note per l'ordine
Volume di consegna
Varianti dei prodotti
11 Risultati
Ricerca
Visualizza disegno quotato
Denominazione
4/2
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
negativo (aperto)
0 [PB/AT]-[ABPT]
4/2
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
positivo (chiuso)
1 [PB/AT]-[A/B/P/T]
4/2
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
positivo (chiuso)
3 [PB/AT]-[ABT/P]
4/2
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
positivo (chiuso)
1/2 [PB/AT]-[PA/BT]
4/2
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
positivo (chiuso)
1/2 [PB/AT]-[PA/BT]
4/2
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
positivo (chiuso)
2/2 [PB/A/T]-[PA/B/T]
4/3
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
negativo (aperto)
0 [PB/AT]-[ABPT]-[PA/BT]
4/3
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
positivo (chiuso)
1 [PB/AT]-[A/B/P/T]-[PA/BT]
4/3
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
positivo (chiuso)
3 [PB/AT]-[ABT/P]-[PA/BT]
4/3
HK SP CAE 12DC
HK SP CAE 24 DC
HK SP CAE 220DC
negativo (aperto)
4 [PA/BT]-[A/B/PT]-[PB/AT]
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Shows 10 of 11
Column selection
Tipo
Bobina magnetica
Copertura
Tipo di pistone
Esecuzione